{"id":18,"date":"2021-02-19T23:25:38","date_gmt":"2021-02-19T23:25:38","guid":{"rendered":"http:\/\/bioviana.com\/en\/?page_id=18"},"modified":"2021-02-20T22:24:29","modified_gmt":"2021-02-20T22:24:29","slug":"18-2","status":"publish","type":"page","link":"http:\/\/bioviana.com\/en\/18-2\/","title":{"rendered":"AT \u2013 PREMIUM CLASS WASTEWATER TREATMENT PLANTS"},"content":{"rendered":"\n<div class=\"wp-block-image\"><figure class=\"alignleft is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/bioviana.com\/wp-content\/uploads\/2016\/10\/at_6.jpg\" alt=\"at_6\" class=\"wp-image-433\" width=\"350\" height=\"424\"\/><\/figure><\/div>\n\n\n\n<p>The small units (<strong>AT6 \u2013 AT20<\/strong>) treat <strong>0,6<\/strong> to <strong>2,7 m\u00b3<\/strong> wastewater per day. Can be used for a summer house, a detached or two-bedroom house, a hotel, a boarding house, a restaurant, a camper and a campsite, a small production company, etc. AT series household wastewater treatment plants are intended for the purification of wastewater in places that cannot be connected to the urban sewage systems or in places where the construction of such a network would be economically unviable or extremely difficult to implement.<\/p>\n\n\n\n<p><strong>Standard equipment<\/strong><\/p>\n\n\n\n<p><strong>\u2713 <\/strong>Wastewater treatment unit<br><strong>\u2713 <\/strong>Green lid<br><strong>\u2713 <\/strong>Control unit AUGUST BASIC<br><strong>\u2713 <\/strong>Blower<br><strong>\u2713 <\/strong>Blower container<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"126\" height=\"126\" src=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/CE-1.png\" alt=\"\" class=\"wp-image-138\"\/><\/figure>\n\n\n\n<p><strong>CE UNE-EN 12566-3<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"126\" height=\"126\" src=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/Pia-1.png\" alt=\"\" class=\"wp-image-139\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"126\" height=\"126\" src=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/Warranty.jpg\" alt=\"\" class=\"wp-image-140\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">&nbsp;<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>TECHNOLOGY<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/Diagram-1.gif\" alt=\"\" class=\"wp-image-60\" width=\"485\" height=\"255\"\/><\/figure><\/div>\n\n\n\n<ol class=\"wp-block-list\"><li>&nbsp;Non-aerated chamber &#8211; labyrinth with vertical flow<\/li><li>&nbsp;Aerated chamber<\/li><li>&nbsp;Final clarification chamber<\/li><li>&nbsp;Integrated retention chamber<\/li><li>&nbsp;Internal recirculation<\/li><li>&nbsp;Sludge recirculation<\/li><li>&nbsp;Fine-bubble diffuser<\/li><li>&nbsp;Flow regulator<\/li><\/ol>\n\n\n\n<div style=\"height:49px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>EFFICIENCY PERFORMANCE<\/strong>&nbsp;<strong>AT6-20<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>BOD\u2085<\/strong> 98.2 %&nbsp; 7,0 mg\/l<\/li><li><strong>SS<\/strong> 97.2 %&nbsp; 12,0 mg\/l<\/li><li><strong>COD<\/strong> 94.4 %&nbsp; 45,0 mg\/l<\/li><li><strong>NH\u2084-N<\/strong> 99.5 %&nbsp; 0,2 mg\/l<\/li><li><strong>N TOT<\/strong> 93.2 %&nbsp; 5,6 mg\/l<\/li><li><strong>P TOT<\/strong> 93.3 %&nbsp; 0,6 mg\/l<\/li><\/ul>\n\n\n\n<div style=\"height:44px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>SPECIFICATIONS<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"649\" src=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/AT-Premium-default-3-1024x649.jpg\" alt=\"\" class=\"wp-image-65\" srcset=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/AT-Premium-default-3-1024x649.jpg 1024w, http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/AT-Premium-default-3-300x190.jpg 300w, http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/AT-Premium-default-3-768x487.jpg 768w, http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/AT-Premium-default-3.jpg 1136w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<ul class=\"wp-block-list\"><li><strong>H<\/strong>&nbsp;Total height (mm)<\/li><li><strong>\u00d8<\/strong>&nbsp;Bottom diameter (mm)<\/li><li><strong>H INLET<\/strong>&nbsp;Inlet height from bottom (mm)<\/li><li><strong>H OUTLET<\/strong>&nbsp;Outlet height from bottom (mm)<\/li><li><strong>\u00d8 INLET<\/strong>&nbsp;Inlet diameter (mm)<\/li><li><strong>\u00d8 OUTLET<\/strong>&nbsp;Outlet diameter (mm)<\/li><\/ul>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n<p><!-- \/wp:post-content --><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<p><!-- \/wp:list --><\/p>\n<p><!-- wp:table --><\/p>\n<figure class=\"wp-block-table\">\n<table style=\"height: 635px;\" width=\"649\">\n<tbody>\n<tr>\n<td><strong>MODEL<\/strong><\/td>\n<td><strong>AT6<\/strong><\/td>\n<td><strong>AT8<\/strong><\/td>\n<td><strong>AT10<\/strong><\/td>\n<td><strong>AT12<\/strong><\/td>\n<td><strong>AT15<\/strong><\/td>\n<td><strong>AT20<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>POPULATION EQUIVALENT<\/strong><\/td>\n<td>4<\/td>\n<td>6<\/td>\n<td>8<\/td>\n<td>10<\/td>\n<td>12<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td><strong>CAPACITY (M\u00b3\/DAY)<\/strong><\/td>\n<td>0.6<\/td>\n<td>0.9<\/td>\n<td>1.2<\/td>\n<td>1.5<\/td>\n<td>1.8<\/td>\n<td>2.7<\/td>\n<\/tr>\n<tr>\n<td><strong>AVERAGE DAILY LOAD (KG\/BDS\u2085)<\/strong><\/td>\n<td>0.24<\/td>\n<td>0.36<\/td>\n<td>0.48<\/td>\n<td>0.60<\/td>\n<td>0.72<\/td>\n<td>1.08<\/td>\n<\/tr>\n<tr>\n<td><strong>EXCESS AMOUNT OF SLUDGE PRODUCED (M\u00b3\/YEAR)<\/strong><\/td>\n<td>1<\/td>\n<td>1.5<\/td>\n<td>2<\/td>\n<td>2.5<\/td>\n<td>3<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td><strong>ELECTRICITY EXPENDITURE (KWH\/DAY)<\/strong><\/td>\n<td>0.6<\/td>\n<td>0.8<\/td>\n<td>1.2<\/td>\n<td>1.6<\/td>\n<td>2.2<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td><strong>WEIGHT (KG)<\/strong><\/td>\n<td>120<\/td>\n<td>145<\/td>\n<td>2012<\/td>\n<td>255<\/td>\n<td>340<\/td>\n<td>430<\/td>\n<\/tr>\n<tr>\n<td><strong>H (MM)<\/strong><\/td>\n<td>1800<\/td>\n<td>2200<\/td>\n<td>2200<\/td>\n<td>2250<\/td>\n<td>2250<\/td>\n<td>2700<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00d8 (MM)<\/strong><\/td>\n<td>1410<\/td>\n<td>1410<\/td>\n<td>1600<\/td>\n<td>1810<\/td>\n<td>2110<\/td>\n<td>2110<\/td>\n<\/tr>\n<tr>\n<td><strong>HEIGHT OF INLET (mm)<\/strong><\/td>\n<td>1300<\/td>\n<td>1700<\/td>\n<td>1700<\/td>\n<td>1700<\/td>\n<td>1700<\/td>\n<td>2200<\/td>\n<\/tr>\n<tr>\n<td><strong>HEIGHT OF OUTLET (mm)<\/strong><\/td>\n<td>1150<\/td>\n<td>1500<\/td>\n<td>1500<\/td>\n<td>1500<\/td>\n<td>1500<\/td>\n<td>2000<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00d8 INLET (mm)<\/strong><\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110\/160<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00d8 OUTLET (mm)<\/strong><\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110<\/td>\n<td>110\/160<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p><!-- \/wp:table --><\/p>\n<p><!-- wp:columns --><\/p>\n<div class=\"wp-block-columns\"><!-- wp:column {\"width\":\"66.66%\"} --><p><\/p>\n<div class=\"wp-block-column\" style=\"flex-basis: 66.66%;\">&nbsp;<\/div>\n<p><!-- \/wp:column --><\/p>\n<p><!-- wp:column {\"width\":\"33.33%\"} --><\/p>\n<div class=\"wp-block-column\" style=\"flex-basis: 33.33%;\">&nbsp;<\/div>\n<p><!-- \/wp:column --><\/p>\n<\/div>\n<p><!-- \/wp:columns --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3><strong>DOCUMENTS<\/strong><\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:columns --><\/p>\n<div class=\"wp-block-columns\"><!-- wp:column --><p><\/p>\n<div class=\"wp-block-column\"><!-- wp:paragraph --><p><\/p>\n<p><strong>Performance results<\/strong><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>The treatment efficiency of the biological treatment step was tested in Testing Institute for Wastewater Technology GmbH (PIA GmbH) Aachen<\/p>\n<p><!-- \/wp:paragraph --><\/p><\/div>\n<p><!-- \/wp:column --><\/p>\n<p><!-- wp:column --><\/p>\n<div class=\"wp-block-column\"><!-- wp:file {\"id\":167,\"href\":\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/PIA.pdf\"} --><p><\/p>\n<div class=\"wp-block-file\"><a href=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/PIA.pdf\">PIA<\/a><a href=\"http:\/\/bioviana.com\/en\/wp-content\/uploads\/2021\/02\/PIA.pdf\" class=\"wp-block-file__button\" download=\"\">Download<\/a><\/div>\n<p><!-- \/wp:file --><\/p><\/div>\n<p><!-- \/wp:column --><\/p><\/div>\n<p><!-- \/wp:columns --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p><!-- \/wp:paragraph --><\/p>","protected":false},"excerpt":{"rendered":"<p>The small units (AT6 \u2013 AT20) treat 0,6 to 2,7 m\u00b3 wastewater per day. Can be used for a summer house, a detached or two-bedroom house, a hotel, a boarding house, a restaurant, a camper and a campsite, a small production company, etc. AT series household wastewater treatment plants are intended for the purification of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-18","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/pages\/18","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/comments?post=18"}],"version-history":[{"count":38,"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/pages\/18\/revisions"}],"predecessor-version":[{"id":185,"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/pages\/18\/revisions\/185"}],"wp:attachment":[{"href":"http:\/\/bioviana.com\/en\/wp-json\/wp\/v2\/media?parent=18"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}